Fixed Fire Detection & Alarm
Function testing of smoke, heat and flame detectors, manual call points and the fire-alarm panel.

Fire-Fighting Appliances
Inspection, refilling and pressure testing of fixed and portable firefighting and detection systems to SOLAS Chapter II-2 and the FSS Code, ahead of Indian port-state inspections.

Overview
An out-of-date extinguisher or an untested fixed installation is a common ground for a port-state control detention, and at Indian ports DG Shipping, MMD surveyors and PSC officers look closely at safety equipment. ARCSHIP arranges FFA servicing so that a vessel arrives with current certificates and equipment that matches its Fire Control Plan.
Work spans fixed CO₂, foam, dry-powder and water-mist installations, sprinkler and deluge systems, detection and alarm panels, portable and wheeled extinguishers, hoses, nozzles and the fire main, firefighter’s outfits, EEBDs and breathing apparatus, completed during the port call and documented with test certificates.
A fixed CO₂ system that cannot be shown to have been weighed and tested correctly is treated as a serious deficiency, which is why weighing and internal examination of the CO₂ bank form part of the annual attendance. Exact due dates come from each vessel’s Safety Equipment Certificate and maker manuals and are mapped against its Indian itinerary.
Fire-fighting and life-saving servicing follow a similar regulatory rhythm, so many owners combine them in one call at Mumbai, JNPT, Cochin or Visakhapatnam. Fixed gas detection can be calibrated on the same visit, and SOLAS-approved replacements supplied for any time-expired item found.
Scope

Function testing of smoke, heat and flame detectors, manual call points and the fire-alarm panel.

Weighing and internal examination of CO₂ banks, with hydrostatic testing of cylinders at the rule-defined intervals.

Condition checks of foam concentrate, with sampling, and servicing of fixed and portable foam equipment.

Pressure and flow testing of water-mist and deluge lines, and inspection of sprinkler systems.

Inspection of firefighter’s outfits and EEBDs against expiry, and function checks and servicing of self-contained breathing apparatus.

Inspection and servicing of fixed and portable dry-powder systems, including condition checks of the powder.
Scope
Annual inspection, refilling and recharging of portable and wheeled extinguishers, with hydrostatic testing of bodies at the 2, 5 and 10-year points.
Cylinder charging, hydrostatic testing and re-certification for composite and steel breathing-apparatus and CO₂ cylinders.
Pressure testing of fire hoses and nozzles, and of the fire main, so the system is proven before a surveyor asks.
FAQ
Yes. ARCSHIP refills, recharges and hydrostatically tests portable and wheeled extinguishers, and hydrotests breathing-apparatus cylinders.
Yes. Fixed CO₂, foam, water-mist and detection systems are inspected, tested and serviced during the vessel’s port call.
Every attendance is documented with test certificates and a consolidated service report for port-state control.
Related services
Send the vessel’s fire-fighting equipment list and its next Indian port, and ARCSHIP will confirm scope, timing and certification.