Fixed Fire Detection & Alarm
Functional testing of fixed fire and smoke detection loops and the alarm circuits they feed.

Fire-Fighting Appliances
Inspection, refilling and testing of fixed and portable fire-fighting systems to SOLAS Chapter II-2 and the FSS Code during an Omani port call.

Overview
Fire safety on merchant ships is governed by SOLAS Chapter II-2 and the FSS Code, and the certificate issued after each servicing is the proof an inspector expects to see. ARCSHIP weighs, tests, refills and certifies the equipment so that the paperwork and the physical condition agree.
Oman’s membership of the Indian Ocean MoU on Port State Control means fire-fighting deficiencies are checked against a shared regional regime. An extinguisher with an expired certificate is treated as an empty one however full it is, so the work is built around certificate dates as much as around the hardware.
Attendances are available at Muscat (Port Sultan Qaboos), Sohar, Khasab, Sur, Duqm and Salalah, and can be combined with LSA servicing and the supply of SOLAS-approved safety products so the vessel does not need a second stop.
Scope

Functional testing of fixed fire and smoke detection loops and the alarm circuits they feed.

Every cylinder weighed or level-checked, discharge hoses and pipework inspected, and release-station alarms and the time-delay unit tested. This is where inspectors most often find lapses.

Fixed and portable foam systems tested and serviced, with foam-concentrate sampling at the intervals set by maker and flag rules.

Water-mist, water-spray and sprinkler installations inspected and function-tested against maker instructions.

Fireman’s outfits, SCBA sets and emergency escape breathing devices inspected, serviced and verified against the vessel’s inventory.

Fixed and portable dry chemical powder units inspected, tested and recharged where required.
Scope
Portable and wheeled extinguishers surveyed, pressure-tested and recharged, with new certificates issued afterwards.
Hydrostatic testing and charge checks of breathing-apparatus and compressed-gas cylinders at the maker’s interval.
Hoses, hydrants and nozzles pressure-tested, with the international shore connection and emergency fire pump checked.
FAQ
A survey of portable and wheeled extinguishers, pressure testing and recharging as required, CO₂ cylinder weighing, hose testing, breathing-apparatus servicing and detection testing, followed by certificates and a service report.
They are typically weighed or level-checked annually and hydrostatically tested every five to ten years depending on cylinder type. The maker’s instructions and flag rules set the exact schedule for each vessel.
ARCSHIP supplies SOLAS-approved safety products to close the gap before the vessel sails, so the call does not end with an open item.
Related services
Send the vessel particulars, the port and the systems on board, and the Muscat team will reply with a proposal and indicative timeline.