Fixed Fire Detection & Alarm
Functional testing of fixed fire and smoke detection and alarm systems and their panels, normally part of the annual examination.

Fire-Fighting Appliances
Servicing of fixed and portable firefighting and detection systems to SOLAS and the FSS Code, for vessels calling on both Saudi coasts.

Overview
An out-of-date extinguisher or an untested fixed system is a frequent cause of port-state control detentions. ARCSHIP inspects, refills and pressure-tests fixed and portable firefighting and detection equipment to SOLAS and the FSS Code, so vessels calling in Saudi Arabia arrive with a documented, in-date system.
Fixed CO₂, foam and water-mist systems, sprinkler and deluge systems, detection and alarm, extinguishers, hoses, the fire main, firefighter’s outfits and breathing apparatus are all in scope. On the Red Sea coast the service is extended through Zamil Offshore’s Western Coast Port Services, which covers extinguisher refill and certification, detection and alarm testing, and fire pump, hydrant and fixed-system work.
Saudi Arabia’s tanker and offshore traffic is heavy, and FFA and LSA due dates often fall together. A combined attendance at Jeddah, Yanbu, Dammam, Jubail or Ras Tanura covers function testing of fixed systems, extinguisher servicing, cylinder hydrotesting and consolidated test certificates.
Scope

Functional testing of fixed fire and smoke detection and alarm systems and their panels, normally part of the annual examination.

Inspection, weighing and hydrostatic testing of fixed CO₂ cylinders. A system that cannot be shown to have been correctly weighed and tested is treated as a serious deficiency.

Testing and servicing of fixed and portable foam systems, including foam-concentrate sampling.

Inspection and functional testing of water-mist, water-spray, sprinkler and deluge systems.

Testing of firefighter’s outfits and servicing of self-contained breathing apparatus, with cylinders hydrotested at maker- and rule-defined intervals.

Inspection, testing and servicing of fixed and portable dry chemical powder systems, with refilling after use.
Scope
Refilling, recharging after use and hydrostatic testing of portable and wheeled extinguishers, with time-expired components replaced.
Hydrostatic testing and re-certification of breathing-apparatus and CO₂ cylinders at maker- and rule-defined intervals, commonly every two, five or ten years.
Pressure testing of fire mains, hydrants, hoses and nozzles, and testing of fire pumps.
FAQ
Yes. Portable and wheeled extinguishers are refilled, recharged and hydrostatically tested, and breathing-apparatus cylinders are hydrotested, usually in the same attendance as LSA servicing.
Yes. Fixed CO₂, foam, water-mist and detection systems are inspected, tested and serviced during the port call, at Gulf ports from our Ras Tanura base and on the Red Sea coast with Zamil Offshore.
Every attendance ends with test certificates and a consolidated service report, so the document file agrees with the equipment on board when an inspector asks for it.
Related services
Send the vessel’s firefighting-equipment list and next Saudi port, and we will confirm scope, intervals and certification.