Fixed and portable firefighting equipment serviced during a call at Colombo, Galle, Hambantota or Trincomalee, to SOLAS and the FSS Code.

Fire-Fighting Appliance (FFA) Servicing, ARCSHIP Sri Lanka

Overview

Keeping firefighting equipment out of the detention list

Fire-fighting appliances are among the most closely inspected systems on a SOLAS vessel, and an out-of-date extinguisher or an untested fixed system is a frequent cause of port-state control detention. ARCSHIP services this equipment to SOLAS, the FSS Code and maker requirements.

For ships calling at Colombo and Sri Lanka’s other ports on the Indian Ocean, the practical task is to match every extinguisher, cylinder and fixed-system due-date to the trading pattern, then place the attendance in a planned call. A fixed CO₂ system that cannot be shown to have been correctly weighed and tested is treated as a serious deficiency at inspection.

Intervals run from monthly and quarterly crew checks through annual examination to hydrostatic testing at two, five and ten years, depending on the equipment, class and flag rules. Send your equipment list and next Sri Lankan port and we confirm scope and certification.

  • Servicing to SOLAS, the FSS Code & maker manuals
  • Refilling & re-charging after use
  • Hydrotest of BA & CO₂ cylinders at set intervals
  • Consolidated test certificates per attendance

Scope

Systems covered on a Sri Lankan call

Fixed Fire Detection & Alarm, ARCSHIP Sri Lanka

Fixed Fire Detection & Alarm

Function testing of detection heads, panels and alarms, a routine item on the annual attendance.

Fixed CO₂ Systems, ARCSHIP Sri Lanka

Fixed CO₂ Systems

Weighing, inspection and function testing of fixed CO₂ systems, and internal examination and hydrotest of cylinders when due.

Foam Systems, ARCSHIP Sri Lanka

Foam Systems

Testing and servicing of fixed foam systems, relevant to the oil and chemical tankers that call at Sri Lankan ports.

Water-Mist & Sprinkler, ARCSHIP Sri Lanka

Water-Mist & Sprinkler

Inspection and function testing of water-mist, sprinkler and deluge systems.

Firefighter’s Outfit & BA, ARCSHIP Sri Lanka

Firefighter’s Outfit & BA

Testing of firefighter’s outfits and self-contained breathing apparatus, including cylinder re-certification.

Dry Chemical Powder, ARCSHIP Sri Lanka

Dry Chemical Powder

Inspection and servicing of dry chemical powder systems, fixed and portable.

Scope

Workshop-type tasks done in port

01

Extinguisher Refilling

Portable and wheeled extinguishers are refilled, recharged and hydrotested, with time-expired parts replaced.

02

SCBA Cylinder Hydrotest

An untested breathing-apparatus cylinder is enough to hold a vessel at berth, so these are tested and re-certified at maker and rule intervals.

03

Fire Main & Hose Testing

Pressure testing of the fire main, hydrants, hoses and nozzles.

FAQ

Frequently asked questions

Can FFA servicing be done in the same call as LSA?

Yes. A combined attendance at Colombo, Galle, Hambantota or Trincomalee reduces visits, paperwork and off-hire.

How often are cylinders hydrotested?

At maker- and rule-defined intervals, typically every two, five or ten years depending on the item. Check each ship’s schedule against its certificates and manuals.

What paperwork do we receive?

Test certificates and a consolidated service report, so the ship can show an inspector what was serviced and when.